Datasets:
image imagewidth (px) 256 6.71k | label class label 3
classes |
|---|---|
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images | |
0images |
MedSeg-7D: Seven Public Medical Segmentation Benchmarks (2D + 3D)
A curated bundle of seven public medical segmentation datasets, packaged with canonical leakage-free splits for the four datasets where one is needed (ACDC patient-level, BraTS2020 volume-level, CVC-ClinicDB video-level, plus seed-fixed image-level for the rest). All raw images and masks are retained at their original resolution; no resizing, no preprocessing baked in.
For the two volumetric MRI datasets (ACDC, BraTS), this release ships both 2D slice extracts and the original 3D NIfTI volumes, so users can choose 2D or 3D pipelines without re-downloading.
This is the dataset-only release that accompanied an evaluation-protocol audit of pixel- vs.\ latent-space diffusion augmentation for medical image segmentation. The bundle is reusable for any 2D medical-segmentation research, not just the original study.
Why this exists. Many existing medical-augmentation papers report non-comparable numbers because each uses a different (often undocumented) train/test split, and several datasets have hidden leakage if split at the image level (CVC same-video frames, ACDC same-patient slices, BraTS same-volume slices). This release fixes one canonical split per dataset so future work can be paired-comparable.
Contents
MedSeg-7D/
βββ README.md
βββ ACDC/ (cardiac MRI, 100 patients)
β βββ images/ 2D slices: patient<id>_frame<f>_slice_<s>.png
β βββ masks/ matching 2D-slice mask filenames (any-structure binary)
β βββ 3D/ ORIGINAL 3D NIfTI volumes (challenge layout)
β β βββ training/
β β β βββ patient001/ Info.cfg + patient001_4d.nii.gz + frame01.nii.gz + frame01_gt.nii.gz + frame12.nii.gz + frame12_gt.nii.gz
β β β βββ ... (100 patients)
β β βββ testing/ 50 held-out patients (challenge test set)
β βββ split_info.json CANONICAL patient-level split (seed=42, 80/20)
β # 2D and 3D share the same 100-patient training cohort. The 3D side
β # additionally ships the official 50 challenge test patients, which the
β # 2D side does NOT include (we re-split the 100 train patients 80/20).
β
βββ BraTS2020/ (brain MRI FLAIR, 369 volumes β 22677 slices)
β βββ images/
β β βββ volume_1/ volume_1_slice_<s>.png (FLAIR channel, ~50-80 slices/vol)
β β βββ volume_2/
β β βββ ... (369 vols)
β βββ masks/
β β βββ volume_1/ matching whole-tumor binary mask
β β βββ ... (369 vols)
β βββ split_info.json CANONICAL volume-level split (seed=42, 295/74)
β # NOTE: BraTS slices are nested into per-volume subdirectories because of
β # HuggingFace's 10000 files-per-directory limit. Filenames preserve the
β # original volume_X_slice_Y.png convention.
β
βββ BraTS2021_3D/ (brain MRI 3D NIfTI, 1251 patients β superset of BraTS2020)
β βββ BraTS2021_00000/ 5 NIfTI files: t1, t1ce, t2, flair, seg (4 modalities + GT)
β βββ BraTS2021_00002/
β βββ ... (1251 patient dirs)
β # IMPORTANT: This is BraTS *2021*, a SUPERSET of BraTS 2020. The 369
β # volumes in our 2D `BraTS2020/` are a subset of the 1251 here. Patient
β # IDs differ between the 2020 and 2021 releases, so split_info.json
β # (volume-level for 2020) does NOT apply to BraTS2021_3D directly. Do
β # not mix 2D and 3D Dice numbers.
β
βββ BUSI/ (breast ultrasound, 780 images)
β βββ images/
β βββ masks/ masks suffixed _mask.png
β
βββ CVC-ClinicDB/ (endoscopy polyp, 612 frames / 29 video sequences)
β βββ PNG/
β β βββ Original/ RGB frames
β β βββ Ground Truth/ binary masks
β βββ TIF/ original release format
β βββ metadata.csv per-frame metadata
β βββ class_dict.csv
β βββ pranet_split.json PRIMARY: PraNet 550/62 image-level split (literature-standard)
β βββ video_split_seed42.json ALTERNATIVE: leakage-free 23/6 video-level split (more rigorous)
β
βββ Kvasir-SEG/ (endoscopy polyp, 1000 images)
β βββ images/ RGB frames
β βββ masks/ binary masks
β βββ bbox/ bounding boxes (auxiliary)
β βββ pranet_split.json PRIMARY: PraNet 900/100 train/test split (literature-standard)
β βββ kavsir_seg_README.md original release notes
β
βββ REFUGE2/ (fundus optic disc, 1200 images = 400 train + 400 val + 400 test)
β βββ train/ {images/, mask/} 400 images
β βββ val/ {images/, mask/} 400 images
β βββ test/ {images/, mask/} 400 images
β
βββ ISIC2018/ (dermoscopy lesions, 2594 train + 100 val + 1000 test)
βββ train/ {images/, masks/}
βββ validation/ {images/, masks/}
βββ test/ {images/, masks/}
Approximate total size: ~18 GB.
Per-dataset details
1. ACDC β Cardiac cine-MRI
| Modality | Cardiac cine-MRI (2D slices) |
| Original task | Multi-class cardiac structure segmentation |
| Patients / slices | 100 / 1841 |
| Mask classes | 4 (background, RV, myocardium, LV) β preserved as in the original release |
| Split type (canonical) | Patient-level, 80 train / 20 test, seed=42 |
| Split file | ACDC/split_info.json |
| Leakage risk | None at patient level. Slice-level random split would leak adjacent slices and inflate Dice ~5 points. |
| Source | ACDC Challenge (MICCAI 2017) |
| Reference | Bernard et al., IEEE TMI 2018 |
| License | Original ACDC license; please refer to the original challenge website. |
2. BraTS 2020 β Brain tumor MRI (FLAIR slices)
| Modality | Brain MRI, FLAIR channel |
| Original task | Multi-class tumor segmentation |
| Volumes / slices | 369 / 22677 (this release: FLAIR-only 2D slices) |
| Mask convention here | Whole-tumor binary (label 1+2+4 β 1) |
| Split type (canonical) | Volume-level, 295 train / 74 test, seed=42 |
| Split file | BraTS2020/split_info.json |
| Leakage risk | None at volume level. Slice-level random would leak adjacent slices ~5 Dice points. |
| Note | Only the FLAIR modality is included. The original BraTS release has T1/T1ce/T2 in addition. If you need multi-modal data, fetch the original release. |
| Source | BraTS 2020 Challenge |
| Reference | Menze et al., IEEE TMI 2015; Bakas et al., 2017 |
| License | Original BraTS license; please refer to the challenge website. |
3. BUSI β Breast ultrasound
| Modality | B-mode breast ultrasound |
| Original task | Lesion segmentation (benign / malignant / normal classes are also available) |
| Images | 780 |
| Mask convention | Binary foreground; mask filenames carry _mask.png suffix |
| Split type (canonical) | Image-level, 80/20, seed=42 |
| Leakage risk | β οΈ The release does not publish patient IDs. Multiple images may come from the same patient. The image-level split is the community standard; "patient-level" cannot be verified from the release. |
| Source | BUSI Dataset (Cairo University) |
| Reference | Al-Dhabyani et al., Data in Brief 2020 |
| License | CC-BY-4.0 |
4. CVC-ClinicDB β Colonoscopy polyp
| Modality | Colonoscopy (RGB endoscopy) |
| Original task | Polyp segmentation |
| Frames / video sequences | 612 / 29 |
| Mask convention | Binary polyp foreground |
| PRIMARY split (literature-standard) | PraNet's 550/62 image-level train/test, used by PraNet, Polyp-PVT, SANet, ESFPNet and most polyp papers |
| Primary split file | CVC-ClinicDB/pranet_split.json |
| ALTERNATIVE split (leakage-free) | Video-level, 23 train / 6 test sequences, seed=42 (489 frames train, 123 frames test) |
| Alternative split file | CVC-ClinicDB/video_split_seed42.json |
| Important note | The PraNet split is image-level and leaks same-video frames across train/test (CVC has 29 underlying sequences). Use it for direct comparison to literature; use video-level for honest leakage-free generalization numbers. The two are not directly cross-comparable in absolute Dice. |
| Source | CVC-ClinicDB |
| Reference | Bernal et al., Computerized Medical Imaging and Graphics 2015 |
| License | Released for academic use; cite the original paper. |
5. Kvasir-SEG β Colonoscopy polyp
| Modality | Colonoscopy (RGB endoscopy) |
| Original task | Polyp segmentation |
| Images | 1000 |
| Mask convention | Binary polyp foreground |
| PRIMARY split (literature-standard) | PraNet's 900/100 train/test (specific file lists), used by PraNet, Polyp-PVT, SANet, ESFPNet and the entire polyp-segmentation literature |
| Primary split file | Kvasir-SEG/pranet_split.json |
| Leakage risk | The release does not publish per-procedure metadata. Image-level is the community standard; per-procedure leakage cannot be audited. |
| Note | Filenames in our release use .jpg (the original Kvasir-SEG extension); PraNet ships them as .png after conversion β basenames match exactly. Auxiliary bbox/ (bounding boxes) included from the original release. |
| Source | Kvasir-SEG |
| Reference | Jha et al., MMM 2020 |
| License | CC-BY-4.0 |
6. REFUGE2 β Fundus optic disc
| Modality | Fundus photography |
| Original task | Optic disc and cup segmentation |
| Images | 1200 = 400 train + 400 validation + 400 test (full official challenge release) |
| Mask convention | Multi-class (BG / disc / cup) preserved; for binary disc segmentation, treat any non-background pixel as foreground |
| Split type | Pre-released 400/400/400 train/val/test split is preserved |
| Leakage risk | None β each image is from a different patient by protocol. |
| Caveat | Modern segmenters reach β₯99.9 Dice on optic-disc segmentation; this dataset is saturated for that task. Use only when you specifically need fundus / glaucoma data. |
| Source | REFUGE2 Challenge |
| Reference | Orlando et al., Medical Image Analysis 2020; Fang et al., Medical Image Analysis 2022 |
| License | Original REFUGE2 license; please refer to the challenge website. |
7. ISIC 2018 β Dermoscopy
| Modality | Dermoscopy |
| Original task | Skin lesion segmentation (Task 1) |
| Images | 2594 train + 100 val + 1000 test (this release: PNG-extracted from the original ISIC 2018 archive) |
| Mask convention | Binary lesion foreground (any-pixel > 0 β 1) |
| Split type | Pre-released train/validation/test split is preserved |
| Leakage risk | The release does not publish patient IDs. Multiple lesions per patient are possible but cross-lesion contamination is generally considered low risk. |
| Source | ISIC 2018 Challenge |
| Reference | Codella et al., 2019; Tschandl et al., Sci. Data 2018 |
| License | CC-BY-NC-4.0 (HAM10000-derived images) |
Comparison to literature and existing HuggingFace cards
We audited the most common split conventions in published segmentation papers (MICCAI / IEEE TMI / MIA / CVPR / NeurIPS) and the two existing HuggingFace community cards for the same datasets, then aligned our defaults where sensible. Summary:
| Dataset | Mainstream literature default | HuggingFace community card | Our default | Verdict |
|---|---|---|---|---|
| CVC-ClinicDB | PraNet's 550/62 image-level files (de facto standard since 2020) | Angelou0516/CVC-ClinicDB: 80/10/10 image-level, ESFPNet split |
PraNet 550/62 (pranet_split.json) as primary; video-level 23/6 (video_split_seed42.json) as leakage-free alternative |
β Matches PraNet exactly + adds a leakage-audit option that nobody else ships |
| Kvasir-SEG | PraNet's 900/100 file list (de facto standard) | kowndinya23/Kvasir-SEG: 880/120 (no test) |
PraNet 900/100 (pranet_split.json) |
β Matches PraNet exactly |
| BUSI | Image-level random; growing minority does 5-fold + de-duplication (BUS-Set, Med Phys 2023, documents duplicate leakage) | n/a | Image-level 80/20 seed=42 | Matches majority; flag: BUSI release has documented duplicates, and patient IDs are not public, so true patient-level splits are not possible |
| ISIC 2018 | Official 2594/100/1000 OR pooled 80/20 | varies | Official 2594/100/1000 preserved | Matches official challenge split |
| REFUGE2 | Official 400/400/400 (train/val/test domain-shift design) | varies | Official train/val/test preserved | Matches official |
| ACDC | Patient-level; TransUNet 70/10/20 of the 100 train OR nnU-Net 5-fold patient CV | rarely correct on HF | Patient-level 80/20 seed=42 (in split_info.json); 3D side also ships official 100-train + 50-test challenge layout |
Stricter than the careless cards; consistent with TransUNet/nnU-Net practice |
| BraTS 2020 | Volume-level; nnU-Net 5-fold patient CV is the most-cited recipe | rarely correct on HF | Volume-level 80/20 seed=42 (295/74) | Matches the careful camp; nnU-Net's 5-fold is a reasonable alternative on the same volumes |
Mainstream papers we cross-checked: PraNet (Fan et al., MICCAI 2020), Polyp-PVT (Dong et al., 2021), ESFPNet (Chang et al., 2024), BUS-Set (Thomas et al., Med Phys 2023), TransUNet (Chen et al., 2021), SwinUNet (Cao et al., 2022), nnU-Net (Isensee et al., Nat. Methods 2021).
Notable disagreements with HuggingFace community cards
kowndinya23/Kvasir-SEG(880/120) merges the test fold into validation, making it non-comparable to PraNet's 900/100. Ours preserves test/val separation.Angelou0516/CVC-ClinicDBdoes image-level 80/10/10 without flagging the same-video frame leakage that affects all 3 splits. We add an explicit video-level split for leakage-free evaluation.- Neither HuggingFace card we found exposes patient-level splits for
ACDC or BraTS β we provide them via
split_info.json.
When to not use our defaults
- If you must directly compare to PraNet/Polyp-PVT numbers, use their released 1450/test files (not in this bundle, but reproducible from the raw images here).
- If you need nnU-Net 5-fold CV on ACDC or BraTS, regenerate folds with the standard nnU-Net recipe β our 80/20 split is a single-fold approximation.
- If you need BraTS 2021 (1251 volumes) instead of 2020 (369), the
3D version is shipped under
BraTS2021_3D/(subset of 2020 patients is included; new 2021-specific patients are added).
Recommended use
For paired-comparison evaluation across methods, lock to the canonical splits in this release:
import json, os
from huggingface_hub import snapshot_download
ROOT = snapshot_download("MaybeRichard/MedSeg-7D", repo_type="dataset")
# ACDC (patient-level)
info = json.load(open(os.path.join(ROOT, "ACDC", "split_info.json")))
train_patients = set(info["train_patients"])
# enumerate slices, check patient ID in filename to assign train/test
# BraTS (volume-level) β slices are nested under per-volume subdirs
info = json.load(open(os.path.join(ROOT, "BraTS2020", "split_info.json")))
train_volumes = set(info["train_patients"]) # key name retained from original
# To enumerate all training slices:
# for vol in train_volumes:
# for img_path in glob.glob(f"{ROOT}/BraTS2020/images/{vol}/*.png"):
# ...
# Kvasir-SEG (PraNet 900/100, literature standard)
info = json.load(open(os.path.join(ROOT, "Kvasir-SEG", "pranet_split.json")))
train_files = set(info["train_files"]) # 900 file basenames (.jpg)
test_files = set(info["test_files"]) # 100 file basenames (.jpg)
# CVC-ClinicDB (PraNet 550/62, literature standard β has same-video leakage!)
info = json.load(open(os.path.join(ROOT, "CVC-ClinicDB", "pranet_split.json")))
train_files = set(info["train_files"]) # 550 frames as <n>.png
test_files = set(info["test_files"]) # 62 frames as <n>.png
# CVC-ClinicDB (video-level 23/6, leakage-free alternative)
info = json.load(open(os.path.join(ROOT, "CVC-ClinicDB", "video_split_seed42.json")))
train_seqs = set(info["train_sequences"])
For the 3D NIfTI versions:
import nibabel as nib
import os
# ACDC 3D (original challenge layout, 100 train + 50 test patients)
patient_dir = os.path.join(ROOT, "ACDC", "3D", "training", "patient001")
img = nib.load(os.path.join(patient_dir, "patient001_frame01.nii.gz")).get_fdata()
gt = nib.load(os.path.join(patient_dir, "patient001_frame01_gt.nii.gz")).get_fdata()
# img shape: (H, W, num_short_axis_slices); gt has 4 classes (0=BG, 1=RV, 2=Myo, 3=LV)
# BraTS 2021 3D (1251 patients, 4 modalities + GT each)
pat = os.path.join(ROOT, "BraTS2021_3D", "BraTS2021_00000")
flair = nib.load(os.path.join(pat, "BraTS2021_00000_flair.nii.gz")).get_fdata()
seg = nib.load(os.path.join(pat, "BraTS2021_00000_seg.nii.gz")).get_fdata()
# seg has 4 classes (0=BG, 1=necrotic, 2=edema, 4=enhancing); whole-tumor = (seg > 0)
For BUSI, the only dataset without a packaged split file, use a seed-fixed image-level 80/20 split:
import numpy as np
def get_image_level_split(n_images, seed=42, train_ratio=0.8):
perm = np.random.RandomState(seed).permutation(n_images)
n_train = int(n_images * train_ratio)
return perm[:n_train], perm[n_train:]
(BUSI's release does not include patient IDs, so a true patient-level split is not possible. See per-dataset notes for caveats.)
Known caveats and good practices
Never use slice-level random split for ACDC or BraTS. Same-patient adjacent slices end up on both sides and inflate Dice ~5 points. Always read
split_info.json.CVC image-level split is leaky. Same-video frames cross train/test. Use the video-level split (
video_split_seed42.json) for clean evaluation. Use image-level only for direct comparison to legacy literature, and label such results as "leakage-audited / auxiliary".BUSI / Kvasir / ISIC do not provide patient IDs. Image-level random is the de-facto community standard; do not claim "patient-level independent" β there is no metadata to verify it.
REFUGE2 saturates at ~99.9 Dice. Don't use it as a downstream evaluator for augmentation studies; use it only when you need a fundus / optic-disc task specifically.
Mask conventions vary across datasets. Some are multi-class (ACDC: 4 classes; BraTS original: 4 classes; REFUGE2: 3 classes). For binary segmentation, use
mask > 0. The released masks here keep the original multi-class labels where applicable (no information lost), so users can choose to binarize as needed.All images and masks are at original resolution. No pre-processing baked in; you can resize per your protocol.
Citation
If this release is useful, please cite both the original dataset papers (see per-dataset references above) and the evaluation-protocol audit that produced these canonical splits:
@inproceedings{medseg7d2026,
title = {An Evaluation-Protocol Audit of Pixel- vs.\ Latent-Space Diffusion
Augmentation for Medical Image Segmentation},
author = {Anonymous},
booktitle = {NeurIPS 2026 (E\&D Track)},
year = {2026}
}
License
This release does not redistribute datasets that are not already
publicly available. Each dataset retains its original license; consult
each per-dataset section above. The split metadata files
(split_info.json, video_split_seed42.json) are released under MIT.
- Downloads last month
- 137